    New - Dielectric Second Stage Regulators

    LV4403BD Series

    New dielectric second stage regulators.

    Application

    RegO’s Dielectric second stage regulators are designed to reduce first stage pressure normally 10PSIG down to burner pressure, normally 11” w.c. and are ideal for medium commercial installations, multiple cylinders installations and normal domestic loads.

    RegO Dielectric second stage regulators are engineered to isolate potential electrical current from metallic piping before entering a building. The use of a separate dielectric union is not necessary because the regulator contains a dielectric union as part of the inlet assembly. Available in both SAE Flare and F.NPT inlet connection.

    Features

    • F. NPT Dielectric Union is made of Brass with inlet Portion Made of Plated Steel
    • M. SAE Flare inlet connection made of solid Brass
    • All second stage features are the same as LV4403B Series

    Ordering Information

    Part Number Inlet Connection Outlet Connection Inlet Material Orifice Size Factory Delivery Pressure Adjustment Range Bonnet Vent Position Vapor Capacity BTU/hr Propane
    3/8" M. Flare = 3
    LV4403B3D 3/8" M Flare 1/2" F. NPT   # 28 Drill 11" w.c. at 10 PSIG Inlet 9" to 13" w.c. Over Inlet 935,000
    LV4403B36D 3/4" F. NPT
    LV4403B3RD* 1/2" F. NPT
    LV4403B36RAD* 3/4" F. NPT 3/16" 1,000,000
    LV4403B36RABD*
    1/2" M. Flare = 1
    LV4403B1D 1/2" M Flare 1/2" F. NPT Brass # 28 Drill 11" w.c. at 10 PSIG Inlet 9" to 13" w.c. Over Inlet 935,000
    LV4403B16D 3/4" F. NPT
    LV4403B16RD
    LV4403B16RAD* 3/16"
    LV4403B16RABD* 1,000,000
    5/8" M. Flare = 5
    LV4403B5D 5/8" M Flare 1/2" F. NPT Brass # 28 Drill 11" w.c. at 10 PSIG Inlet 9" to 13" w.c. Over Inlet 935,000
    LV4403B56D 3/4" F. NPT
    LV4403B56RD*
    LV4403B56RAD* 3/16"
    LV4403B56RABD* 1,000,000
    1/2" - 3/4" F.NPT Union  
    LV4403B4D 1/2" F.NPT 1/2" F. NPT Brass & Plated Steel # 28 Drill 11" w.c. at 10 PSIG Inlet 9" to 13" w.c. Over Inlet 935,000
    LV4403B46D 3/4" F. NPT
    LV4403B66D 3/4" F.NPT
    LV4403B46RD 1/2" F.NPT
    LV4403B66RD 3/4" F.NPT
    LV4403B66RAD 3/16" 1,000,000
    LV4403B66RABD*

    *Backmount Design

    Maximum flow based on 10 PSIG inlet and 9” w.c. delivery pressure



    More Articles Like This One

     

     

    Like this Article? Why not Share!

     



    Easily order new parts, easily locate our branches, and easily check your orders on the go. That’s the Tarantin App. Download it today.

    Apple DownloadGoogle Play Download

    Don’t have an online ordering account? CLICK HERE to sign up today.

    Location

    Address: 86 Vanderveer Road
    Freehold, NJ 07728

    Phone: 1 800.922.0724

    Fax: 1 732.780.5173

    Follow Us:

     

     

     

     

      

    facebook icon twitter icon youtube icon